portfolio_page-template-default,single,single-portfolio_page,postid-587,bridge-core-2.3.9,qode-page-transition-enabled,ajax_fade,page_not_loaded,,vertical_menu_enabled,qode_grid_1300,side_area_uncovered_from_content,qode-child-theme-ver-1.0.0,qode-theme-ver-27.9,qode-theme-bridge,disabled_footer_top,qode_header_in_grid,wpb-js-composer js-comp-ver-6.2.0,vc_responsive

Determination of the degree of chloride concentration in the maritime port

About This Project

Core extraction to determine the chloride concentration profile in a concrete structure located in the port area. Analysis of samples by grinding concrete slabs at different depths (profile grinder) and subsequent potentiometric titration to obtain chloride concentration profiles as a function of depth.